Currency
Exchange Calculator | BS
EN ISO 9001-2008 | Customer
Satisfaction Survey | H
& S Data Sheets |
Health & Safety Data Sheet
|
Effective Date: |
13-01-2003 |
|
Product Name: |
|
|
Product Type |
Non-Woven H/E wiper with integral ANTI-BACTERIAL agent |
|
Supplier: |
Wiper Supply
Services Ltd, |
|
Preparation Composition: |
AMOLDEN
-MC Super (MCP Super) (Mould/fungus
proofing agent) |
|
Hazard Identification: |
Not classified as hazardous - Essentially NOT TOXIC in use. |
|
Health Effects |
Eyes: None |
|
Skin: No adverse reaction recorded. |
|
|
Ingestion: Essentially Non Toxic - cloths should not be ingested. |
|
|
Inhalation: Non Toxic - n/a |
|
|
FIRST AID MEASURES: |
N/A |
|
Emergency Measures: |
Fire Extinguishing Media: Use water spray, foam, dry chemical, powder etc; |
|
Handling & Storage |
Storage should be dry, out of direct sunlight, away from heat/ignition. |
|
Exposure Control: |
N/a |
|
Respiratory Protection: |
Not required |
|
Physical & Chemical Properties |
Disposable wipers with antibacterial properties, designed to reduce/inhibit the growth of bacteria within the cloths during and after use.. |
|
Stability & Reactivity: |
Stable under normal conditions. Avoid extremes of temperature. There are no known materials to avoid. |
|
Toxicological Info: |
The constituents of this product are classified as NON-TOXIC |
|
Disposal: |
Dispose in accordance with all local/national regulations. |
|
Transport Info: |
This product is "NOT HAZARDOUS" for transport |
|
Regulatory Info: |
This product DOES NOT require special H &S labelling as it is NOT CLASSIFIED. |
|
National Legislation: |
UK Legislation: SI 1993/1746 Chemicals (Hazard Info: & Packaging) regulations 1993. SI 1988/1657: The Control of Substances Hazardous to Health Regulations. |
|
Biocidal Report |
Test
material: 80gsm Hydra spunlaced Nonwoven Cloths (Novette Super) |
|
Laboratory
Test Results on Antibacterial |
|
|
We submitted samples of our NOVETTE SUPER products to an INDEPENDENT testing laboratory. The results clearly show that our NOVETTE SUPER wipers really do inhibit the growth of bacteria in the cloth, whilst in use.
Against
S aureus -
99.98% success rate* * % reduction when compared with the number of microorganisms present at zero time. Here are how the results were obtained: |
|
|
Performed
by Microbiological Consultant Services
Test:
Assessment of Antibacterial finishes on Textile Materials: Method: A piece of the test material weighing 1g is inoculated with 1ml of buffered sodium chloride solution containing approximately 105 colony forming units of one of the test bacteria. The innoculated test piece is then incubated in a sealed container at 36o for 24 hours. At the end of the incubation period, the test piece is extracted with 9ml of a diluent containing 2% Tween 80 and plated in Tryptone Soya Agar containing Tween 80 and Lecithin as inactivators. The plates are incubated at 36o for 48 hours and any colonies produced are counted. The number of bacteria present at zero time is calculated by performing counts on the inoculum. |
|
|
Results:
* % reduction when compared with the number of microorganisms present at zero time. |